990-7031D, Revision 5 5/01 APC Smart-UPS Uninterruptible Power Supply Models 1400XLT, 2200XLT, 3000T, 5000T User’s Manual

Strona 2

990-7031D, Revision 5 5/01 43 Expand the rails so that it spans from the front rack post to the back rack post. Replace the two screws

Strona 3

990-7031D, Revision 5 5/01 52. Connect the Batteries Note: All UPSs ship with the batteries disconnected. In addition, 5000 VA units have the batter

Strona 4

990-7031D, Revision 5 5/01 63U Rack Mount Units 1. Reach into the finger pull and open the front cover. Swing the cover open as shown.

Strona 5 - Table of Contents

990-7031D, Revision 5 5/01 73. Connect Power and Equipment to the UPS • Connect the UPS line cord (L6-30 plug) into the electrical outlet. • Use

Strona 6

990-7031D, Revision 5 5/01 8Connect Computer Interface Port (Optional) Power management software and interface kits can be used with this UPS. Use o

Strona 7 - Installation

990-7031D, Revision 5 5/01 9 With the UPS plugged in, press and release the large upper on/test button to supply power to the loads. The loads are im

Strona 8 - Position the UPS

990-7031D, Revision 5 5/01 10The SmartTrim LED comes on to indicate that the UPS is compensating for a high voltage. SmartBoost The SmartBoost LED co

Strona 9 -

990-7031D, Revision 5 5/01 11Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Be

Strona 10 - 990-7031D, Revision 5 5/01

990-7031D, Revision 5 5/01 12Battery Replacement Procedure - Tower Units 5000 VA 1. Grasp the top edge of the bottom front cover and tilt it out.

Strona 11 - 2. Connect the Batteries

990-7031D, Revision 5 5/01 13Battery Replacement Procedure - 3U Rack Mount Units 1. Reach into the finger pull and open the front cover. Sw

Strona 12

Entire contents copyright ©1999 by American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited

Strona 13 - Initial Startup

990-7031D, Revision 5 5/01 14Battery Replacement Procedure - 5U Rack Mount Units 5000 VA 1. Reach into the finger pull and open the front cover.

Strona 14 - Operating Instructions

990-7031D, Revision 5 5/01 15 Batteries must be recycled. Deliver the battery to an appropriate recycling facility or ship it to the supplier in the

Strona 15

990-7031D, Revision 5 5/01 16User Configuration Items Note: Setting these items requires optional software or hardware. Function Factory Default Us

Strona 16

990-7031D, Revision 5 5/01 172200 0.13 0.35 0.63 0.93 1.25 1.67 2.00 2.42 2.83 3.17 3.58

Strona 17 - Replacing the Battery

990-7031D, Revision 5 5/01 18Tower and 5U Rack Mount Models - 3000 & 5000 VA Models Typical On-Battery Run Time Versus Load, in Hours Load 3000

Strona 18 - 1400-3000 VA

990-7031D, Revision 5 5/01 19Specifications 1400 VA 2200 VA 3000 VA 5000 VA Acceptable input voltage 0 - 325 VAC Input voltage (on-line operatio

Strona 19

990-7031D, Revision 5 5/01 20 Troubleshooting Use the chart below to solve minor UPS installation problems. Contact APC Technical Support Staff for

Strona 20

990-7031D, Revision 5 5/01 21• Weak batteries. Do another self test to see if it clears. • Replacement batteries not connected properly. Confirm

Strona 21

990-7031D, Revision 5 5/01 22EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAM

Strona 22 - User Configuration Items

990-7031D, Revision 5 5/01 23Appendix A: XL Information When used with external battery packs, the extended run (XL) UPS offers longer run times than

Strona 23

990-7031D, Revision 5 5/01 Smart UPS Safety Guide English This Safety Guide contains important instructions that should be followed during installati

Strona 24

990-7031D, Revision 5 5/01 24Smart-UPS XL models are not designed to know how many external battery packs are connected to them. You must program th

Strona 25 - Specifications

990-7031D, Revision 5 5/01 25Use the HyperTerminal Program to Change the Number of External Battery Packs HyperTerminal is used for Windows 95, Window

Strona 26 - Troubleshooting

990-7031D, Revision 5 5/01 26Appendix B: Types of Racks and Mounting Hardware This appendix describes the hardware required for the different types

Strona 27 - Limited Warranty

990-7031D, Revision 5 5/01 27Appendix C: Transporting Your Smart-UPS Follow these guidelines if you need to ship the UPS to another location. These

Strona 28

990-7031D, Revision 5 5/01 2

Strona 29 - Smart-UPS Battery Protocol

990-7031D, Revision 5 5/01 Table of Contents Introduction ...

Strona 31

990-7031D, Revision 5 5/01 1Introduction This Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags and surges from rea

Strona 32

990-7031D, Revision 5 5/01 2Installing your UPS requires five steps: 1. Position the UPS in the desired location. For rack mount units this may inc

Strona 33

990-7031D, Revision 5 5/01 3** Caution: Check the rack to make sure it won’t tip after moving the mounting brackets. 1. Determine where in the rac