EDA 1200 Nodes
The 288-line IP DSLAM EDN288x is ordered, delivered, installed, and
commissioned as one pre-assembled, pre-cabled, and tested unit. EDN288x
consists of 24 x 12-line IP DSLAMs (EDN312x), one Ethernet Controller Node
(ECN330), 24 numbered Ethernet cables, and a power cable, all assembled in
an 11 HU chassis. The EDN288x chassis can be plugged directly into existing
19” or ETSI racks and connected to upstream Ethernet over copper or fiber.
EDN288x is power fed from a standard telecom graded –48 V DC power
supply. Traffic from the EDN288x is delivered on one or two Gigabit Ethernet
fiber interfaces.
Expanded version of EDN288x
Figure 28 Different configurations of EDN288x
For redundancy or double uplink, the EDN288x can be extended with one
additional Ethernet Controller Node (ECN330) configured as switch as shown
in Figure 26 on page 50. Mechanical expansion is available by adding one
ECN330, Ethernet cables, and mounting brackets.