Podsumowanie treści

Strona 1 - Installation

InstallationMGE ™ Galaxy™ 3500XR Battery Enclosure 10-40 kVA 380/400/415 V10-30 kVA 208/220 V

Strona 2

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation6Remove the cable landing cover and bottom platesTo access the cabl

Strona 3 - Contents

7MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationRemove the XR Battery ModulesHeavy: Use two people to lift the bat

Strona 4

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation8Anchor the UPS and additional XR Battery or UPS Enclosure(s) (opti

Strona 5 - THESE INSTRUCTIONS

9MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationNote: The U-shaped interconnection brackets are 1-2 mm higher than

Strona 6 - System arrangements

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation106. Insert the interconnection plates between the two enclosures.

Strona 7 - (23.6 in) is recommended

11MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationRun the CablesConnect Power in Installations with Busbars Warning

Strona 8 - Floor anchoring brackets

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation12Install busbars 523 mm (20.59 in) UPS System with the UPS placed

Strona 9 - Prepare for Cables

13MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation523 mm (20.59 in) UPS system with the UPS placed to the right (se

Strona 10

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation14352 mm (13.85 in) UPS system with the UPS placed to the right (se

Strona 11 - Remove the XR Battery Modules

15MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation352 mm (13.85 in) UPS system with the UPS placed to the left (see

Strona 13

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation16Connect Power in Installations with CablesInstall power cables Se

Strona 14

17MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationInstall power cables between two XR Battery Enclosures. 1. Feed t

Strona 15 - Run the Cables

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation18Connect Communication Cables1. Feed the cable from pin connection

Strona 16 - Install busbars

19MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationConnect the EPOConnect the EPO to the UPS and the XR Battery Encl

Strona 17

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation20Final Mechanical AssemblyLevel the Enclosures (L-shaped Floor Anc

Strona 18

21MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationInstall battery-securing and floor-anchoring brackets 1. Install

Strona 19

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation22Reinstall the Enclosure PlatesReinstall the cable landing cover p

Strona 20 - Install power cables

23MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationSpecifications Battery voltage and current Recommended cable size

Strona 21 - From UPS

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation24Post-Installation ChecklistUse the following checklist to verify

Strona 23 - Connect the EPO

ContentsMGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationiSafety ...

Strona 26

11/2009990-2195B-001*990-2195B-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any o

Strona 27 - Specifications

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationiiFinal Mechanical Assembly...

Strona 28 - Post-Installation Checklist

1MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationSafetyIMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONSWarni

Strona 29

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation2Prepare for Floor-Anchoring (optional)Note: If floor anchoring and

Strona 30

3MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationHole positions for a stand-alone UPS enclosure with L-shaped ancho

Strona 31

MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery Installation4Hole positions for up to four UPS units in parallel with U-shaped

Strona 32 - *990-2195B-001*

5MGE™ Galaxy™ 3500 10-40 kVA 380/400/415 V, 10-30 kVA 208/220 V Battery InstallationPrepare for CablesRemove the front panel1. Use a coin or similar t