Strona 1 - Operation

Operation Smart-UPS® VT10-40 kVA – 400 V10-30 kVA – 208 V10-30 kVA – 200 V

Strona 2

Overview – User Interface4 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Menu treeThe menu tree provides a quick overview of the f

Strona 3 - About this Manual

Overview – User Interface990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 5CautionThe display provides access to more functions than

Strona 4

6 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Operation Operation ModesThe UPS has different operation modes. If the installatio

Strona 5 - Contents

990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 7Operation ProceduresHow to turn into bypassSingle System – turning into internal b

Strona 6

Operation – Operation Procedures8 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Turn the internal mechanical bypass lever upwards

Strona 7

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 9Parallel System – turning into external bypass. PW

Strona 8 - Overview

Operation – Operation Procedures10 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to turn into normal operation Single System –

Strona 9

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 11Parallel System – turning into normal operation f

Strona 10 - Menu tree

Operation – Operation Procedures12 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to turn load OFF/ON via the display interface

Strona 11 - Overview – User Interface

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 13How to view the Status screensUse the UP/DOWN key

Strona 13 - Operation Procedures

Operation – Operation Procedures14 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to view Logging and StatisticsThe View Log. V

Strona 14 - Runtime: 0hr 0m

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 15How to use the Diags screenThe Diags. View troubl

Strona 15 - – Turn Load off – Yes

Operation – Operation Procedures16 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to perform a total power offTotal power off –

Strona 16

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 17Total power off – single system with MBP. Total p

Strona 17

Operation – Operation Procedures18 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Total power off – isolating one UPS in a parallel

Strona 18

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 19How to perform a restart Restart – single system

Strona 19 - View Parameters

Operation – Operation Procedures20 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Restart – single system with MBP. NoteAuto-detect

Strona 20 - UP/DOWN

Operation – Operation Procedures990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 21Restart – parallel system. WarningOnly trained pe

Strona 21 - How to use the Diags screen

22 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001ConfigurationSettingsHow to change the Clock and the Alarms in the Setting menuCl

Strona 22 - XR Enclosure

Configuration – Settings990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 23Alarm thresholds. The procedure for changing the Alarm th

Strona 23

1 Smart-UPS® VT 10-40 kVA, 400 V, 208 V, 200 V - Operation 990-2282A-001About this ManualIMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis man

Strona 24 - SC two times to get back

Configuration – Settings24 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001The Beeper setup. In the Beeper setup you can choose betw

Strona 25 - How to perform a restart

990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 25MaintenanceParts ReplacementHow to determine if you need a replacement partTo det

Strona 26 - – Turn Load on – Yes, turn

Maintenance – Parts Replacement26 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to store the battery modulesThe battery module

Strona 27 - – Yes, turn Load on

Maintenance – Parts Replacement990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 27User interface (front). Network Management Card w

Strona 28 - Configuration

Maintenance – Parts Replacement28 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to replace a Network Management CardHow to rep

Strona 29 - Time: 13:45:51

Maintenance – Parts Replacement990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 29Battery module. One Battery Module consists of fou

Strona 30 - Configuration – Settings

Maintenance – Parts Replacement30 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001How to remove and install battery locks (if availa

Strona 31 - Maintenance

Maintenance – Parts Replacement990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 31Follow the below procedures if you need to change

Strona 32

Maintenance – Parts Replacement32 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Install the Battery Module in the lowest availabl

Strona 33 - User interface (front)

990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 33TroubleshootingStatus and Alarm MessagesThis section lists the status and alarm m

Strona 34

About this Manual2 Smart-UPS® VT 10-40 kVA, 400 V, 208 V, 200 V - Operation 990-2282A-001How to find updates to this manualYou can check for updates

Strona 35 - 4 x 24 kg / 4 x 53 lbs

Troubleshooting – Status and Alarm Messages34 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001Int. Mech. Bypass Switch Open.The inte

Strona 36

Troubleshooting – Status and Alarm Messages990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 35PBus Communication Fault on Cable 2.Co

Strona 37

Troubleshooting – Status and Alarm Messages36 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001System Not Synchro-nized to Bypass.The

Strona 39 - Troubleshooting

01/2007990-2282A-001*990-2282A-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any o

Strona 40

Contents990-2282A-001 Smart-UPS® VT 10-40 kVA, 400 V, 208 V, 200 V – Operation iSafety...

Strona 41

ii Smart-UPS® VT 10-40 kVA, 400 V, 208 V, 200 V – Operation 990-2282A-001Maintenance...

Strona 42

990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 1SafetyFor safety reasons, the trained user is only allowed to operate the display

Strona 43

2 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 990-2282A-001OverviewUser Interface Interface areaThe four LEDs to the left of the display indi

Strona 44 - *990-2282A-001*

Overview – User Interface990-2282A-001 Smart-UPS® VT 10-40 kVA 400V, 208V, 200V – Operation 3Main Menu Screen. From the Main Menu Screen it is possibl

Komentarze do niniejszej Instrukcji

Brak uwag